Download e-book for iPad: Stereotactic Body Radiation Therapy by Simon S. Lo, Bin S. Teh, Jiade J. Lu, Tracey E. Schefter

By Simon S. Lo, Bin S. Teh, Jiade J. Lu, Tracey E. Schefter

ISBN-10: 364225604X

ISBN-13: 9783642256042

Stereotactic physique radiation treatment (SBRT) has emerged as a tremendous leading edge therapy for varied basic and metastatic cancers. This e-book offers a accomplished and up to date account of the physical/technological, organic, and scientific features of SBRT. it is going to function an in depth source for this speedily constructing therapy modality. The organ websites coated contain lung, liver, backbone, pancreas, prostate, adrenal, head and neck, and feminine reproductive tract. Retrospective reviews and potential medical trials on SBRT for varied organ websites from world wide are tested, and toxicities and basic tissue constraints are mentioned. This e-book positive aspects particular insights from world-renowned specialists in SBRT from North the USA, Asia, and Europe. it will likely be helpful interpreting for radiation oncologists, radiation oncology citizens and fellows, clinical physicists, scientific physics citizens, scientific oncologists, surgical oncologists, and melanoma scientists.

Show description

Read or Download Stereotactic Body Radiation Therapy PDF

Similar neurosurgery books

Read e-book online Book MRI in Ischemic Stroke PDF

The imaging of stroke has gone through major alterations because of the speedy growth in imaging know-how. This quantity, comprising 3 components, is designed to supply a complete precis of the present position of MR imaging in sufferers with ischemic stroke. the 1st half outlines the medical shows of stroke and discusses the diagnostic efficacy and healing influence of MR imaging.

Read e-book online Stereotactic Body Radiation Therapy PDF

Stereotactic physique radiation treatment (SBRT) has emerged as an immense leading edge therapy for varied fundamental and metastatic cancers. This booklet offers a complete and updated account of the physical/technological, organic, and medical points of SBRT. it's going to function an in depth source for this swiftly constructing remedy modality.

Download e-book for iPad: Problem Halswirbelsäule: Aktuelle Diagnostik und Therapie by B. Kügelgen, A. Hillemacher (auth.), Dr. med. Bernhard

Bei reicher Bebilderung bietet das Buch eine F}lle hoch- aktueller und praxisrelevanter ]bersichten zur Diagnostik und Therapie von Erkrankungen der Halswirbels{ule mit vielen neuen Ergebnissen.

Surgery of the autonomic nervous system by Jonathan A. Hyam, Erlick A. C. Pereira, Alexander L. Green PDF

'Neurobiology of Addictions' highlights one of the most promising study components of the swiftly increasing box of dependancy. it is going to be precious as a pragmatic instrument for clinicians, study investigators, and trainees - either in dependancy and in different health problems with overlapping mechanisms - in addition to an informative source for non-technical readers who're attracted to habit or psychological well-being coverage.

Additional resources for Stereotactic Body Radiation Therapy

Example text

1993) and Menke et al. (1994). They employed video stereophotogrammetry as a means of evaluating the repositioning accuracy of a specially designed head holder for fractionated radiotherapy. Shortly thereafter, Bova et al. (1997) adopted the methodology for cranial radiosurgery. 05 mm deflections in a radiosurgery head holder. In 1999, the group at the University of Chicago developed a video-based system for patient positioning (Johnson et al. 1999). The system used two CCD cameras to display real-time subtraction images for analysis of misalignment of head and neck patients.

14 The spinal radiosurgery approach described by Medin et al combined frame-based localization with kV projection image guidance using a mobile radiography unit be performed despite the fact that (a) the patient had moved from the time of the initial CT and (b) the target could not be directly visualized in the treatment room. 17 mm. The methodology was subsequently evaluated in a swine model. Radionics briefly considered commercializing the methodology. Two groups have combined in-room CT imaging with linac delivery for stereotactic irradiation of intra- and extra-cranial targets.

9 Drawing from the 1993 patent awarded to John Adler, Russell Schonberg and Peter Schonberg, with an early version of the CyberKnife continue to be used to this day in the treatment of many patients every year. Meeks et al. (2000) described a double-focused miniature MLC developed in conjunction with Wellhofer Dosimetrie (Schwarzenbruck, Germany). 3 Dedicated Linac Radiosurgery Systems Through the 1990s, the use of linacs in radiosurgery remained controversial, based largely on the assertion by some practitioners that linac-based systems, with multiple moving parts, could not match the accuracy of gamma units.

Download PDF sample

Stereotactic Body Radiation Therapy by Simon S. Lo, Bin S. Teh, Jiade J. Lu, Tracey E. Schefter


by George
4.0

Rated 4.87 of 5 – based on 35 votes